Description
What it does
Every System2 board talks to the others over one two-wire cable: the network. (Its proper name is a CAN bus, which is where the CAN Bridge gets its name.) That cable is designed to be one line. It runs from board to board, with the TERM jumper fitted on the board at each of its two ends, and no branches anywhere. Wire it like that and the network is rock solid.
The CAN Bridge keeps a layout to that rule when one simple line is no longer enough. It has three network connections, and each one is the start of a separate section: a line of its own, with its own two ends. Every message that arrives on one section is sent out again, fresh and at full strength, on the other two, in both directions. To your boards it is still one network, so a button on a panel in one section works a point on a board in another, just as it always did. On the wire, every section is short, tidy and wired the way it should be.
The CAN Bridge is invisible to the other boards on the network, just like the switch on an Ethernet network at home or in an office: the computers never know it is there, it simply passes their messages along. It has no address and no settings, and nothing on your other boards changes when you add one.
Why you might want one
- A mimic panel, control panel or fiddle yard on a branch. A lead running off the main cable to a few boards (a dropper) is the most common way a network ends up out of spec, which simply means not wired the way it is designed to be. A bridge where the branch joins turns it into a proper section of its own.
- A long layout. Club, exhibition, loft and garden layouts can outgrow one run of cable. Each section of a bridge can be as long as a whole System2 network, so the layout can stretch further.
- Lots of boards. Every board adds a little load to the cable. Each section only carries its own boards, so bridges let a layout grow well past what one cable comfortably takes.
- Exhibitions. A layout that is taken apart, carried in a van and rebuilt in a busy hall meets loose plugs and electrical interference. With bridges, trouble on one section stays on that section and the rest of the layout keeps running. When the fault clears, the section joins back in by itself.
- Finding faults fast. With the optional screen and lights you can see which section has gone quiet or is having trouble, instead of crawling under the baseboards to find out.
If your layout is on one short, tidy run of cable, you do not need one.
1. Bring a branch back into spec
2. Make a long layout longer
3. Add a third section, or more
The colour screen, push button and status lights (optional)
The CAN Bridge works perfectly well on its own, tucked away under the baseboard. The option adds three parts so you can see what the network is doing from the front of the layout. They come loose, not fitted: you mount them in your own control panel or fascia, wherever suits you, and connect them to the bridge behind it.
It looks after itself
There is nothing to set up and nothing to install: no Wi-Fi, no app and no PC. Wire it in, fit the TERM jumpers and switch on. The bridge keeps an eye on each of its sections all the time. If one has a fault, such as a plug pulled out or a lead knocked during a running session, that section rides it out while the other two carry on running the layout, and it joins back in by itself as soon as the fault clears. A section with a fault cannot flood the others with repeated messages.
Proven on Making Tracks
On Pete Waterman’s Making Tracks, up to seven CAN Bridges are linked together on one network when the layouts are joined up for special events. They sit where each mimic panel joins the main cable, which is exactly the job in the first two drawings above, and they are what keeps a layout of that size running cleanly.
Specification
- Three network connections, each a separate section, with every message passed between them in both directions.
- Works with every System2 board on the standard two-wire network (CAN-H and CAN-L).
- A TERM jumper for each connection, so the bridge can be the end of any of its sections.
- Power: 12 V DC, from the same supply as your other System2 boards.
- Screw terminals for the network and the power, and power and running lights on the board.
- Nothing to set up: no Wi-Fi, no app, no PC.
- Option: a 1.54-inch colour screen (240 × 240), a push button and six status LEDs (a sending and a receiving light for each connection), supplied loose for you to mount in your control panel.
- Usually made to order and sent within 1 week.
Documentation
System2 CAN Bridge / Repeater — User Guide — the complete guide: the wiring drawings above, where the TERM jumpers go, every light and every page of the screen, and what to look at when something goes wrong. There is a print button at the top if you would like it on paper.
Questions and answers
Why do I need this if the wiring is supposed to be simple?
You don’t, if your layout is wired the way System2 is designed: one cable running from board to board in a single line, with the TERM jumper fitted on the board at each of its two ends and no branches anywhere. Messages travel cleanly along a line like that, and plenty of layouts never need anything more.
Real layouts are not always that tidy. A control panel, mimic box or fiddle yard ends up on a lead hanging off the main cable, a long layout outgrows one run of cable, or a big one gathers a great many boards. That is out-of-spec wiring, and it is where messages start to go missing. A CAN Bridge turns each part back into a simple line.
If you are lucky enough to own a large or complex layout, isn’t it nice to know we’ve got you covered?
Can I link bridges together?
Yes. Each connection on a bridge is a section of its own, so you can fit another bridge on any section and keep adding them as the layout grows. On Making Tracks we have up to seven linked together when the layouts are joined up for special events.
Will my other boards know it is there?
No. The CAN Bridge is invisible to every other board on the network, just like the switch on an Ethernet network: the computers never know it is there, it simply passes their messages along. It has no address and no settings, and nothing on your other boards needs changing when you add one.
Where do the TERM jumpers go?
Every section needs exactly two TERM jumpers, one on the board at each end, and none in between. The bridge has its own TERM jumper for each of its three connections. Fit it when the bridge is at the end of that section, as it is in most of the drawings above. Leave it off when a cable runs in and straight out again through the bridge, as the main cable does in the second drawing, because then the bridge is in the middle of that section, not at its end.
Do the screen, button and LEDs come fitted?
No. They come loose, so you can mount them in your own control panel or fascia, wherever suits you, and connect them to the bridge behind it. The bridge itself can then live out of sight under the baseboard.
Do I need the screen?
No. The bridge does its job just the same without it. The screen, button and lights are there so you can watch what the network is doing. They earn their keep on a big or exhibition layout, where seeing straight away which section has a problem saves a lot of crawling about under the baseboards.
What happens if one section has a fault?
Only that section is affected. If a plug is pulled out or a lead is knocked, that section rides it out while the others keep the layout running, and it joins back in by itself as soon as the fault is cleared. Nothing needs restarting.
Does it matter whether I run DCC or analogue?
No. The bridge only carries the System2 network’s messages and never touches track power, so it works the same on DCC and analogue layouts.
What power does it need?
12 V DC from the same supply as your other System2 boards, connected to its own screw terminals.
How soon will it arrive?
Each one is made to order, and is usually sent within 1 week.